Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Esp Cardiol (Engl Ed) ; 77(4): 290-301, 2024 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37516313

RESUMO

INTRODUCTION AND OBJECTIVES: Repetitive ambulatory doses of levosimendan are an option as a bridge to heart transplantation (HT), but evidence regarding the safety and efficacy of this treatment is scarce. The objective of the LEVO-T Registry is to describe the profile of patients on the HT list receiving levosimendan, prescription patterns, and clinical outcomes compared with patients not on levosimendan. METHODS: We retrospectively reviewed all patients listed for elective HT from 2015 to 2020 from 14 centers in Spain. RESULTS: A total of 1015 consecutive patients were included, of whom 238 patients (23.4%) received levosimendan. Patients treated with levosimendan had more heart failure (HF) admissions in the previous year and a worse clinical profile. The most frequent prescription pattern were fixed doses triggered by the patients' clinical needs. Nonfatal ventricular arrhythmias occurred in 2 patients (0.8%). No differences in HF hospitalizations were found between patients who started levosimendan in the first 30 days after listing and those who did not (33.6% vs 34.5%; P=.848). Among those who did not, 102 patients (32.9%) crossed over to levosimendan after an HF admission. These patients had a rate of 0.57 HF admissions per month before starting levosimendan and 0.21 afterwards. Propensity score matching analysis showed no differences in survival at 1 year after listing between patients receiving levosimendan and those who did not (HR, 1.03; 95%CI, 0.36-2.97; P=.958) or in survival after HT (HR, 0.97; 95%CI, 0.60-1.56; P=.958). CONCLUSIONS: Repetitive levosimendan in an ambulatory setting as a bridge to heart transplantation is commonly used, is safe, and may reduce HF hospitalizations.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Piridazinas , Humanos , Simendana/uso terapêutico , Cardiotônicos/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/cirurgia , Hidrazonas/uso terapêutico , Piridazinas/uso terapêutico
2.
Ultramicroscopy ; 250: 113757, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37207610

RESUMO

We describe a setup that is used for high-frequency electrical sample excitation in a cathode lens electron microscope with the sample stage at high voltage as used in many synchrotron light sources. Electrical signals are transmitted by dedicated high-frequency components to the printed circuit board supporting the sample. Sub-miniature push-on connectors (SMP) are used to realize the connection in the ultra-high vacuum chamber, bypassing the standard feedthrough. A bandwidth up to 4 GHz with -6 dB attenuation was measured at the sample position, which allows to apply sub-nanosecond pulses. We describe different electronic sample excitation schemes and demonstrate a spatial resolution of 56 nm employing the new setup.

3.
JACC Cardiovasc Imaging ; 15(11): 1883-1896, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36357131

RESUMO

BACKGROUND: Global circumferential strain (GCS) and global radial strain (GRS) are reduced with cytotoxic chemotherapy. There are limited data on the effect of immune checkpoint inhibitor (ICI) myocarditis on GCS and GRS. OBJECTIVES: This study aimed to detail the role of GCS and GRS in ICI myocarditis. METHODS: In this retrospective study, GCS and GRS from 75 cases of patients with ICI myocarditis and 50 ICI-treated patients without myocarditis (controls) were compared. Pre-ICI GCS and GRS were available for 12 cases and 50 controls. Measurements were performed in a core laboratory blinded to group and time. Major adverse cardiovascular events (MACEs) were defined as a composite of cardiogenic shock, cardiac arrest, complete heart block, and cardiac death. RESULTS: Cases and controls were similar in age (66 ± 15 years vs 63 ± 12 years; P = 0.20), sex (male: 73% vs 61%; P = 0.20) and cancer type (P = 0.08). Pre-ICI GCS and GRS were also similar (GCS: 22.6% ± 3.4% vs 23.5% ± 3.8%; P = 0.14; GRS: 45.5% ± 6.2% vs 43.6% ± 8.8%; P = 0.24). Overall, 56% (n = 42) of patients with myocarditis presented with preserved left ventricular ejection fraction (LVEF). GCS and GRS were lower in myocarditis compared with on-ICI controls (GCS: 17.5% ± 4.2% vs 23.6% ± 3.0%; P < 0.001; GRS: 28.6% ± 6.7% vs 47.0% ± 7.4%; P < 0.001). Over a median follow-up of 30 days, 28 cardiovascular events occurred. A GCS (HR: 4.9 [95% CI: 1.6-15.0]; P = 0.005) and GRS (HR: 3.9 [95% CI: 1.4-10.8]; P = 0.008) below the median was associated with an increased event rate. In receiver-operating characteristic (ROC) curves, GCS (AUC: 0.80 [95% CI: 0.70-0.91]) and GRS (AUC: 0.76 [95% CI: 0.64-0.88]) showed better performance than cardiac troponin T (cTnT) (AUC: 0.70 [95% CI: 0.58-0.82]), LVEF (AUC: 0.69 [95% CI: 0.56-0.81]), and age (AUC: 0.54 [95% CI: 0.40-0.68]). Net reclassification index and integrated discrimination improvement demonstrated incremental prognostic utility of GRS over LVEF (P = 0.04) and GCS over cTnT (P = 0.002). CONCLUSIONS: GCS and GRS are lower in ICI myocarditis, and the magnitude of reduction has prognostic significance.


Assuntos
Miocardite , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Miocardite/induzido quimicamente , Miocardite/diagnóstico por imagem , Miocardite/complicações , Volume Sistólico , Função Ventricular Esquerda , Inibidores de Checkpoint Imunológico , Estudos Retrospectivos , Valor Preditivo dos Testes , Troponina T
4.
Rev Esp Cardiol (Engl Ed) ; 75(1): 60-66, 2022 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34253459

RESUMO

INTRODUCTION AND OBJECTIVES: Heart retransplantation (ReHT) is controversial in the current era. The aim of this study was to describe and analyze the results of ReHT in Spain. METHODS: We performed a retrospective cohort analysis from the Spanish Heart Transplant Registry from 1984 to 2018. Data were collected on donors, recipients, surgical procedure characteristics, immunosuppression, and survival. The main outcome was posttransplant all-cause mortality or need for ReHT. We studied differences in survival according to indication for ReHT, the time interval between transplants and era of ReHT. RESULTS: A total of 7592 heart transplants (HT) and 173 (2.3%) ReHT were studied (median age, 52.0 and 55.0 years, respectively). Cardiac allograft vasculopathy was the most frequent indication for ReHT (42.2%) and 59 patients (80.8%) received ReHT >5 years after the initial transplant. Acute rejection and primary graft failure decreased as indications over the study period. Renal dysfunction, hypertension, need for mechanical ventilation or intra-aortic balloon pump and longer cold ischemia time were more frequent in ReHT. Median follow-up for ReHT was 5.8 years. ReHT had worse survival than HT (weighted HR, 1.43; 95%CI, 1.17-1.44; P<.001). The indication of acute rejection (HR, 2.49; 95%CI, 1.45-4.27; P<.001) was related to the worst outcome. ReHT beyond 5 years after initial HT portended similar results as primary HT (weighted HR, 1.14; 95%CI, 0.86-1.50; P<.001). CONCLUSIONS: ReHT was associated with higher mortality than HT, especially when indicated for acute rejection. ReHT beyond 5 years had a similar prognosis to primary HT.


Assuntos
Transplante de Coração , Rejeição de Enxerto/epidemiologia , Humanos , Pessoa de Meia-Idade , Sistema de Registros , Reoperação , Estudos Retrospectivos , Espanha/epidemiologia
5.
J Am Coll Cardiol ; 77(12): 1503-1516, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33766256

RESUMO

BACKGROUND: Myocarditis is a potentially fatal complication of immune checkpoint inhibitor (ICI) therapy. Data on the utility of cardiovascular magnetic resonance (CMR) T1 and T2 mapping in ICI myocarditis are limited. OBJECTIVES: This study sought to assess the value of CMR T1 and T2 mapping in patients with ICI myocarditis. METHODS: In this retrospective study from an international registry of patients with ICI myocarditis, clinical and CMR findings (including T1 and T2 maps) were collected. Abnormal T1 and T2 were defined as 2 SD above site (vendor/field strength specific) reference values and a z-score was calculated for each patient. Major adverse cardiovascular events (MACE) were a composite of cardiovascular death, cardiogenic shock, cardiac arrest, and complete heart block. RESULTS: Of 136 patients with ICI myocarditis with a CMR, 86 (63%) had T1 maps and 79 (58%) also had T2 maps. Among the 86 patients (66.3 ± 13.1 years of age), 36 (41.9%) had a left ventricular ejection fraction <55%. Across all patients, mean z-scores for T1 and T2 values were 2.9 ± 1.9 (p < 0.001) and 2.2 ± 2.1 (p < 0.001), respectively. On Siemens 1.5-T scanner (n = 67), native T1 (1,079.0 ± 55.5 ms vs. 1,000.3 ± 22.1 ms; p < 0.001) and T2 (56.2 ± 4.9 ms vs. 49.8 ± 2.2 ms; p < 0.001) values were elevated compared with reference values. Abnormal T1 and T2 values were seen in 78% and 43% of the patients, respectively. Applying the modified Lake Louise Criteria, 95% met the nonischemic myocardial injury criteria and 53% met the myocardial edema criteria. Native T1 values had excellent discriminatory value for subsequent MACE, with an area under the curve of 0.91 (95% confidence interval: 0.84 to 0.98). Native T1 values (for every 1-unit increase in z-score, hazard ratio: 1.44; 95% confidence interval: 1.12 to 1.84; p = 0.004) but not T2 values were independently associated with subsequent MACE. CONCLUSIONS: The use of T1 mapping and application of the modified Lake Louise Criteria provides important diagnostic value, and T1 mapping provides prognostic value in patients with ICI myocarditis.


Assuntos
Inibidores de Checkpoint Imunológico/efeitos adversos , Imageamento por Ressonância Magnética , Miocardite/induzido quimicamente , Miocardite/diagnóstico por imagem , Idoso , Técnicas de Imagem Cardíaca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/patologia , Estudos Retrospectivos
6.
Thromb Res ; 179: 20-27, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31075697

RESUMO

INTRODUCTION: Lack of INR controls might affect the adherence to direct oral anticoagulants (DOAC). The vast majority of studies that addresses adherence to anticoagulants are retrospective and based on pharmacy refill data. Our aim was to compare the adherence between vitamin K antagonists (VKA) and DOAC and to analyze the clinical relevance of non-adherence. MATERIALS AND METHODS: A prospective two-arm observational cohort study was performed in two Spanish public hospitals. Adherence was assessed by Medication Event Monitoring System. Relationship between adherence and events during follow-up and time in therapeutic range (TTR) in the VKA group were analyzed. RESULTS: 257 patients were included (132 DOAC and 125 VKA). Monitoring time was 120 days (101-133). Patients in VKA group showed higher taking adherence (97.9% vs. 95.8%) and less non-adherent patients of >5% and >10% of the doses, without differences in >20% of the doses. Taking adherence was strongly associated with TTR (AUC: 0.89, CI 95%: 0.81-0.97 of TTR for detection of non-adherent patients of >10% of doses). During a follow-up of 1.8 years (1.6-2) non-adherent patients of >5% of doses presented more thromboembolic events (HR 6.1, CI95% 1.3-28.1). CONCLUSIONS: Although adherence to oral anticoagulant therapy was excellent, it was higher to VKA than to DOAC. Time in therapeutic range was highly sensitive to few missed doses of AVK. Non-adherence of >5% of prescribed doses had high clinical relevance.


Assuntos
Anticoagulantes/uso terapêutico , Vitamina K/antagonistas & inibidores , Idoso , Anticoagulantes/farmacologia , Fibrilação Atrial , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos
7.
Ultramicroscopy ; 171: 63-69, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27620135

RESUMO

A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500MHz storage ring RF frequency.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...